72 Vol. 42 No. 1 - February 2020 Issue Frequency Response A further point which received our attention was the obvious need for close frequency response limits, if the maximum length of trunk network was to be achieved. This requirement was made more stringent by the extra bandwidth involved and it was decided that specification of plus or minus a quarter of a dB, per repeater, in response flatness was required. It was also noted that this response should be maintained during adjustment of both the gain and tilt of the amplifier. There is little point in designing an amplifier with a completely flat frequency response, when viewed in the maximum gain position, if the operation of either the attenuator/equaliser network, or the slope and gain controls, cause the response to be appreciably degraded. Automatic Level Control Systems As the equipment we were designing was for large networks, it was essential that a form of control be applied which would compensate for variations due to temperature effects, not only on the amplifiers but on the cable network. It is not sufficient to ensure that great care is taken with the stability of the amplifier with varying temperature, circuits must also be used which compensate for changes of loss in the cable used on the network. Several systems have been employed for compensating for the changing characteristics of the cable network on a VHF relay system. These can in the main be divided into two types, (1) passive networks, and (2) active networks. The passive type of network normally employed is the use of a temperature sensing device which senses the ambient temperature of the cable or amplifier, and adjusts the gain or slope of the amplifier to suit the prevailing temperature conditions. The principal difficulties encountered in this type of system, are in matching the compensation networks to the characteristics of the cable network, and in placing the equaliser at a point where it senses and compensates the cable temperature changes. A cable may take many hours to respond to a change in ambient temperature, whereas a simple thermal sensor changes in minutes. A further difficulty is that this type of network cannot sense and compensate for small changes in amplifier gain or even variations on the network accessories. It was considered therefore, that while a passive network would probably be adequate for small systems or as an additional compensation method, some form of active control would have to be employed on large systems. The type of control which has becomemost popular in recent years is the use of a pilot carrier generator, and a pilot sensing device. As is well known this system transmits a pilot carrier which is detected at an amplifier, and used to control the gain of the amplifier. This is a form of servo control where the ALC unit corrects the system gain assuming that when the pilot is set to the correct output level all other signals will also be correct. It is worth considering the workings of ALC systems in some detail since the use of a good ALC unit is the key to large system stability. Fig.4 shows the change from nominal level of 5 cable lengths each with 20dB loss at 300MHz. At 44MHz these would have a loss of 7.7dB. If we study this plot we can see that the change of loss is greatest at 300MHz. This is because cable changes with temperature at the rate of .002dB per dB loss per °C.As the cable loss is greater at 300MHz the variation of attenuation due to temperature is therefore correspondingly greater. The reduction in loss for a 20°C drop in temperature is 1½dB at 44MHz and 4dB at 300MHz. Conversely when temperature rises by 20°C the loss increases by 1½dB at 44MHz and 4dB at 300MHz. We can see in Fig.5 the effect of controlling the level by means of a 297MHz pilot. The lower line shows the change Fig.4. Five cable lengths, 20dB loss at 300MHz. Change from nominal due to +20°C. Fig.5. Effect of 297MHz pilot controlling a flat gain change. Fig.6. 74.25MHz pilot controlling a flat gain change. due to a temperature rise of +20°C. In a single pilot carrier system with the pilot set at 297MHz, the ALC unit corrects the level at this frequency. However, it does not correct the slope which has been imposed by the cable's loss characteristic. The overall result therefore is that whilst the level is now corrected at 297MHz, the 44MHz end of the band has risen by 2½dB. In Fig.6 the effect of controlling the level with a pilot at 74.25MHz, is evident. Whilst the pilot correctly adjusts the level at 74.25MHz, the change is not sufficient at 300MHz. Therefore this end of the band remains about 2½dB down on the nominal level from the archive

RkJQdWJsaXNoZXIy OTIxNzg=