20587 - SCTE Broadband Feb2020 COMPLETE v3
78 Vol. 42 No. 1 - February 2020 Issue from the archive are talking of differences in second order intermodulation between the two sides of the amplifier of 1 - 3dB in 60dBs, or as little as ten parts in 1000. Accurate matching must be achieved, not just at one frequency, but over the whole band from 44 - 300MHz. The one en- couraging factor in this result is shown by the dotted line, 6dBs above the zero line. With a push-pull circuit you win a 6dB improvement in second order intermodulation - free! - as in the soap powder advertisements. This is because, as the two stages are effectively in parallel they can be run at a 3dB lower level resulting in an overall improvement in second order intermodulation of 6dB. By careful design, it was found possible to make a repeatable output stage which would allow us to achieve the design figure of 115dBmV B2F from the repeater amplifier. It is interesting to note that as further stages are added to the push-pull amplifier, that is for example a three section amplifier instead of a two section, good cancellation becomes more difficult to achieve. This was a further reason why every effort was made to optimise the first two stages to minimise their second order intermodulation distortion thus allowing us to use only two stages of push-pull amplification. Fig.19. A block diagram of a complete assembly is shown in Fig.19. Here we see that the output of the trunk amplifier module feeds into a 1½dB splitter which has three spurs. The first feeds signals to the automatic level and slope control unit from which this selects the two pilots necessary to control the gain and slope networks in the trunk repeater amplifier. The second output from this off-trunk splitter feeds to the bridger amplifier. From the bridger there is provision for plug-in splitters to allow up to four further distribution lines. The third output from this splitter is to a directionally coupled output monitor point. The use of a directional coupler ensures that the signal on this monitor corresponds to those on the output of the amplifier and that the reading is not seriously influenced by any cable or equipment following the amplifier. The trunk and bridger amplifier modules are in fact physically similar; are inter- changeable and are built in three gain versions. This means that any gain bridger unit may be used with any trunk unit. The gain range on both the trunk and bridger module lies between the 18½dB plug-in module and the 29dB plug-in module. With the trunk working at the nominal correct operating level there is sufficient gain in the bridger amplifier to allow a launch from the bridger at its maxi- mum rated output. This high gain in the bridger means that in many cases the need for further line extension amplifiers is either eliminated or considerably reduced. In the case of less complete assemblies the modules which are not required are simply removed and where necessary 75 ohm load units fitted. The main chassis for the unit is standard. At any time a trunk amplifier can be raised to the status of an automatic level and slope control unit or have a bridger unit added. On a relay system where extensions and modifications to the network are quite often necessary, changes to the amplifier configurations are readily achieved. This article will conclude in the next issue of Broadband Journal .
Made with FlippingBook
RkJQdWJsaXNoZXIy OTIxNzg=